Incident
open
#15
RT-QFX10K-FKT2 downtime
At around 02:40 am today RT-QFX10K-FKT2 went down unexpectedly. We are checking the cause
Occurred: 2026-11-23 02:20
(Europe/Berlin)
At around 02:40 am today RT-QFX10K-FKT2 went down unexpectedly. We are checking the cause
Updates
-
2026-11-23 02:54:41 UTC
The router is back up and services were restored at 03:32 AM.
We are currently looking to the root cause.
-
2026-11-23 04:21:44 UTC
We found cause of the incident:
Orange announced maintenance for the time of the incident. After Orange shut down the ports, a chain of events was triggered on QFX10K-FKT2:
We had a VXLAN tunnel configured that was not in use anymore.
The next hop for this tunnel endpoint was static routed to Orange.
As soon as the LAG interface went down the PFE was reading a non existent memory address and this triggered a segmentation fault and subsequently caused all three linecards to crash because the Orange ports are spread over all three linecards.
We have now removed the VXLAN config and do not expect the issue to occur again.